GAS SPRINGS NEW GENERATION

125 PED 2014/68/EU subject to alterations COMPACT GAS SPRING .00425. 100 150 200 250 300 350 400 450 50 60 70 80 90 100 110 120 130 140 150 50 5 6 0 10 1516 20 25 30 32 35 40 45 050 1,0 016 2,2 2,1 2,0 1,9 1,8 1,7 1,6 1,5 1,4 1,3 1,2 1,1 006 010 025 032 040 force daN charge pressure (bar) stroke in mm pressure rise factor nominal stroke Initial spring force versus charge pressure Spring force Diagram displacement versus stroke rise Pressure rise factor accounts for displacement but not external influences! Note: Initial spring force at 150 bar = 425 daN Worn gas springs cannot be repaired, they have to be replaced completely. Pressure medium: Nitrogen N2 Max. filling pressure: 150 bar Min. filling pressure: 20 bar Working temperature: 0°C to +80°C Temperature related force increase: ± 0.3%/°C Max. recommended extensions per minute: approx. 50 to 100 (at 20°C) Max. piston rod speed: 0.8 m/s * not for stroke 10 ±0,25 l 13,5 5 6 ø10 min. l 4,8 s ø25±0,3 ø23 R1 ø23 R1 2490.15.00420. 2 ø14±0,2 M5x7 (2x) M6 ø11 M4* s Order No (Stroke max.) lmin. l Gas volume [l] Weight [kg] 2490.15.00420.006 6 50 56 0.004 0.13 2490.15.00420.010 10 60 70 0.006 0.16 2490.15.00420.016 16 75 91 0.01 0.18 2490.15.00420.025 25 95 120 0.016 0.23 2490.15.00420.032 32 108 140 0.019 0.24 2490.15.00420.040 40 125 165 0.024 0.28 2490.15.00420.050 50 145 195 0.03 0.31 2490.15.00420. Compact gas spring

RkJQdWJsaXNoZXIy MTIwNzY0