GAS SPRINGS NEW GENERATION

39 S>max V>max ISO P>max PED 2014/68/EU subject to alterations GAS SPRING, STANDARD 400 500 0 300 200 100 50 60 70 80 90 100 110 120 130 140 150 .00470. 125 1,0 1,6 200 100 013 025 038 050 063 080 100 125 160 200 150 160 175 50 63 75 80 25 38 0 5 1013 010 1,5 1,4 1,3 1,2 1,1 force daN charge pressure (bar) stroke in mm pressure rise factor nominal stroke Initial spring force versus charge pressure Spring force Diagram displacement versus stroke rise Pressure rise factor accounts for displacement but not external influences! Note: Initial spring force at 150 bar = 470 daN Order No for spare parts kit: 2480.15.00500 (Stroke length 10 and 13 not repairable) Gas spring without valve Order No (example): 2480.15.00500. .P Pressure medium: Nitrogen N2 Max. filling pressure: 150 bar Min. filling pressure: 20 bar Working temperature: 0°C to +80°C Temperature related force increase: ± 0.3%/°C Max. recommended extensions per minute: approx. 40 - 80 (at 20°C) Max. piston rod speed: 1.8 m/s 16,5 ø20 3,5 4 2 10,5 I min. l ±0,25 ø40 M6 2480.15.00500. s ø45±0,3 ø43 R1 ø36 ø20±0,2 5,5 M8x13 (2x) /1 8 G ø16,4 s Order No (Stroke max.) lmin. l Gas volume [l] Weight [kg] 2480.15.00500.010 10 95 105 0.016 0.9 2480.15.00500.013 12.7 97.7 110.4 0.018 1 2480.15.00500.025 25 110 135 0.03 1.09 2480.15.00500.038 38 123 161 0.043 1.2 2480.15.00500.050 50 135 185 0.054 1.29 2480.15.00500.063 63.5 148.5 212 0.067 1.38 2480.15.00500.080 80 165 245 0.083 1.5 2480.15.00500.100 100 185 285 0.102 1.64 2480.15.00500.125 125 210 335 0.126 1.85 2480.15.00500.160 160 245 405 0.16 2.1 2480.15.00500. Gas spring, Standard

RkJQdWJsaXNoZXIy MTIwNzY0