GAS SPRINGS NEW GENERATION

73 S>max V>max ISO P>max PED 2014/68/EU subject to alterations GAS SPRING POWERLINE 015 007 013 019 010 7 100 125 050 025 25 32 38 75 80 0 125 100 50 63 10131519 1,0 1,9 1,8 1,7 1,6 1,5 1,4 1,3 1,2 1,1 075 080 063 032 038 50 0 50 180 100 170 160 150 140 130 120 110 100 60 70 80 90 200 150 .00170. 5 force daN charge pressure (bar) stroke in mm pressure rise factor nominal stroke Initial spring force versus charge pressure Spring force Diagram displacement versus stroke rise Pressure rise factor accounts for displacement but not external influences! Note: Initial spring force at 180 bar = 170 daN Worn gas springs cannot be repaired, they have to be replaced completely. Pressure medium: Nitrogen N2 Max. filling pressure: 180 bar Min. filling pressure: 20 bar Working temperature: 0°C to +80°C Temperature related force increase: ± 0.3%/°C Max. recommended extensions per minute: approx. 40 - 100 (at 20°C) Max. piston rod speed: 1.8 m/s 1) Not for fastening I min. I ±0,25 ø19 17 1 ±0,25 s M6x6 6 ø17 R1 ø17 R1 M6 2487.15.00170. ø11 1) s Order No (Stroke max.) lmin. l Gas volume [l] Weight 2487.15.00170.007 7 37 44 0.002 0.06 2487.15.00170.010 10 40 50 0.003 0.06 2487.15.00170.015 15 45 60 0.004 0.07 2487.15.00170.019 19 49 68 0.005 0.07 2487.15.00170.025 25 55 80 0.006 0.08 2487.15.00170.038 38 68 106 0.01 0.09 2487.15.00170.050 50 80 130 0.012 0.11 2487.15.00170.063 63 93 156 0.016 0.12 2487.15.00170.075 75 110 185 0.013 0.14 2487.15.00170.080 80 115 195 0.02 0.14 2487.15.00170.100 100 135 235 0.024 0.16 2487.15.00170.125 125 160 285 0.03 0.19 2487.15.00170. Gas spring POWERLINE