GAS SPRINGS NEW GENERATION

75 S>max V>max P>max PED 2014/68/EU subject to alterations GAS SPRING POWERLINE 0 50 50 180 170 160 150 140 130 120 110 100 60 70 80 90 100 150 200 250 300 350 .00320. 7 25 32 38 75 80 0 125 100 50 63 5 10131519 100 125 050 019 025 1,0 1,9 1,8 1,7 1,6 1,5 1,4 1,3 1,2 1,1 075 080 063 032 038 013 010 015 007 force daN charge pressure (bar) stroke in mm pressure rise factor nominal stroke Initial spring force versus charge pressure Spring force Diagram displacement versus stroke rise Pressure rise factor accounts for displacement but not external influences! Note: Initial spring force at 180 bar = 320 daN Worn gas springs cannot be repaired, they have to be replaced completely. Pressure medium: Nitrogen N2 Max. filling pressure: 180 bar Min. filling pressure: 20 bar Working temperature: 0°C to +80°C Temperature related force increase: ± 0.3%/°C Max. recommended extensions per minute: approx. 40 - 100 (at 20°C) Max. piston rod speed: 1.8 m/s 1) Not for fastening ±0,25 l 17 6 ø15 min. l 1 2487.15.00320. s M6 ø25±0,25 ø23 R1 ø23 R1 M6x6 1) Order No smax. lmin. L Gas volume [l] Weight [kg] 2487.15.00320.007 7 37 44 0.005 0.1 2487.15.00320.010 10 40 50 0.006 0.1 2487.15.00320.015 15 45 60 0.008 0.11 2487.15.00320.019 19 49 68 0.01 0.12 2487.15.00320.025 25 55 80 0.013 0.13 2487.15.00320.038 38 68 106 0.019 0.15 2487.15.00320.050 50 80 130 0.024 0.17 2487.15.00320.063 63 93 156 0.03 0.19 2487.15.00320.075 75 110 185 0.036 0.22 2487.15.00320.080 80 115 195 0.038 0.23 2487.15.00320.100 100 135 235 0.047 0.26 2487.15.00320.125 125 160 285 0.058 0.3 2487.15.00320. Gas spring POWERLINE

RkJQdWJsaXNoZXIy MTIwNzY0