FIBRO - Standard Parts

F397 ≈ G / P . . . . . . . . . . . . … . . . . . . /G / / DIAPHRAGM PRESSURE SWITCH ADAPTER BLOCK SCREW CONNECTION GE-G1/4-G1/8 Mounting example: Description: The adapter 2480.00.45.10, in combination with the diaphragm pressure switch 2480.00.45.01 or 2480.00.45.02, permits filling pressure monitoring similar to the control fittings 2480.00.30.02. When the filling pressure falls below a certain level, the diaphgram pressure switch issues a signal or switches the machine off. 2480.00.45.01 2480.00.45.02 2480.00.45.00.01.18.14 Screw connection GE - G 1/8 - G 1/4 for control valve with screw connection G 1/8 G A/F / G / 2480.00.45.10 Technical data Diaphragm pressure switch 2480.00.45.01 Setting range 20-250 bar Tolerance ±5.0 bar Overpressure protection 350 bar max. voltage 250 V 2480.00.45.02 Setting range 10-80 bar Tolerance ±1.6 bar Overpressure protection 350 bar max. voltage 250 V Note: For individual monitoring of springs see adapter 2480.00.45.10 Wiring diagram for diaphragm pressure switch