FIBRO - Standard Parts

D60 „ X “ b s b1 b2 3 r 1 3 d X 5° l 1 d7 d6 r61 d H7 min. 5 8 l l 7 r f61 d M12 15° l 2 l 5 l 6 24 r d5 2022.12. GUIDE PILLAR WITH PILOT TAPPER AND GROOVE, TO MERCEDES-BENZ STANDARD Material: Steel, surface hardened Surface hardness: 60 + 4 HRC, Hardness penetration 1,5 + 1 mm Execution: ground Ø d1 = 80 without central hole with 1 lifting thread M12 from Ø d1 = 100 with central hole (through) and with 2 lifting threads M8 Note: Secure with snap ring 2061.48. Guide pillar is recommended to be used only with guide elements with solid lubricant. Matching guide combinations, see selection matrix at the beginning of chapter D. Assembly guide lines / Dimensional requirements and tolerances at the end of chapter D. Mounting example Ordering Code (example): Guide pillar with pilot tapper and groove, to Mercedes-Benz Standard = 2022.12. Diameter of conduit d1 125 mm = 125. Length l1 355 mm = 355 Order No = 2022.12. 125. 355 2022.12. Guide pillar with pilot tapper and groove, to Mercedes-Benz Standard d1 80 100 125 160 d3 - 50 65 95 d5 - 62 82 119 d6 71.4 89.9 114.9 148.9 r 3 3 4 4 r1 1.05 1.3 1.3 1.3 l2 50 50 50 50 l5 100 125 140 180 l6 4 4 5 5 l7 21 31 31 31 l8 20 30 30 30 b1 2.1 2.6 2.6 2.6 b2 4.2 5.2 5.2 5.2 l1 280 ● 315 ● ● 355 ● ● ● 400 ● ● ● 450 ● ● ● ● 500 ● ● 560 ●