FIBRO - Standard Parts

F87 R2 d3 d4 d1 d2 2x45° 2x45° 35 25 40 f max. 60 100 2531.7. subject to alterations SETTING-UP BUMPER, ROUND Description: Setting up bumpers are used for setting down and setting up tools and replace shear pins. Material: FIBROFLEX® Hardness 95 Shore A Attention: Setting up bumpers are not suitable for continuous use. To prevent damage when setting down tools, ensure that the setting up bumpers are large enough to withstand 1.5 times the weight of the tool (see table). Implementation: 1. When setting up slowly move the ram into the bottom position. 2. Clamp the tool, then move the ram back to the top position (with the setting up bumper compressed to a height of 60 mm). 3. After setting up, remove the setting up bumpers and place them in the storage hole on the tool. 60 100 Tool set down Spacer block Tool tted Downward stroke Mounting example 2531.7. Setting-up bumper, round Admissible tool weight Load capacity Load capacity Load capacity in kg for in daN bei in daN bei in daN bei 4 setting up bumpers Order No d1 d2 d3 d4 f max. f=20 f=25 f=40 f=20/safety factor 1,5 2531.7.063 63 86 16 18 40 2,200 2,800 4,800 5,800 2531.7.080 80 111 20 22 40 3,500 4,600 8,500 9,300 2531.7.100 100 136 20 22 40 5,000 6,700 11,700 13,300 2531.7.125 125 171 25 28 40 7,600 9,400 18,900 20,200

RkJQdWJsaXNoZXIy MTIwNzY0